WE10 type 3x series wet solenoid operated directional valve
NG 10 pressure up to 31.5 MPa flowrate up to 1200 L/min
|
|
Model description
|
|
|
|
|
|
Symbol
|
|
|
|
|
Principle of operation
|
|
|
|
|
|
WE type directional control valve is operated by the solenoid to control flow direction and on-off the valve is mainly comprised of valve body (1) one or two solenoids (2) control spool (3) and one or two reset
springs(4)
Under static condition the control spool (3) is on center or original position by reset spring (4) cexcept for pulse valve The control spool(3) is operated by wet
solenoid(2)
To ensure for right function the solenoid armature sleeve must be filled with
oil
The force of solenoid(2) is acting on control spool (3) it will push on required position while on static position. The oil allowably flows from P to A and B, to T or P to B and A to T When the solenoid (2) is off the control spool(3) will be pushed on original position by reset spring(4) Elective urgent operation (5) can control the spool (3) motion when the solenoid is off the spool position is not certain.
|
|
|
|
|
|
WE10.3X/OC…type (only spool A. C and D possibility)
This type is double solenoid for two position directional valve it has not positioner and reset spring When the solenoid is off the spool position is not
certain
WE10.3X/OFC…type (pulse operation) with positioner (only spool A. C and D
possibility) This type is double solenoid for two position directional valve it has positioner but not reset spring When the solenoid is off the spool position is fixed Therefore it
needn't to supply electricity for the solenoid continyously.
Insert throttling plug (WE10…3X/…/B..type)When operating the valve if producing large flowrate that exceeds power limit of the valve which is allowable it needs an insert throttling plug.The plug is mounted on P port of the valve
|
|
Technical Paramter
|
|
|
| Mounting position |
|
|
|
Slective |
| The hightest ambient temperature |
|
t |
℃ |
To 50 |
| Weight |
|
|
|
单个接头 |
| |
With 1 solenoid valve |
m |
kg |
4.7(=); 3.9(-) |
| |
With 2 solenoid valve |
m |
kg |
6.3(=);
4.7(-) |
| Max
working pressure |
Port A, B, P |
MPa |
31.5 |
|
Port T |
MPa |
To 21(=);
to 16(-)
If working pressure exceeds allowance pressure for spool A and B of the valve port T must be as leakage port |
| Max flow |
L/min |
To 120 |
|
Flow |
Spool V |
mm2 |
11(A/B→T);
10.3(P→A/B) |
| Area |
Spool W |
mm2 |
2.5(A/B→T) |
|
Switching position |
Spool Q |
mm2 |
5.5(A/B→T) |
Hydraulic oil
1) apply to perbunan seal viton seal
2) for use only viton seal |
Mineral oil
(HL, HLP) DIN51 524 1);
Quick biologic dissolve oil according to VDMA 24 568
HETG (rape seed oil)
HEPG(polyglycol); HEES(synthetic ester)2);
Other oil as required |
|
Oil temperature changing range |
℃ |
-30 to +80(with perbunan seal) |
| -20 to +80 (with viton seal) |
| Viscosity range |
mm2/s |
2.8
to 500 |
|
Contaminant degree |
The high contaminant class of oil is the ninth class of NAS 1638 recommend to use the oil filter with minimal filter fineness β10≥75 |
|
|
Electricity data
|
|
|
| Volt type |
|
DC |
AC |
| Available volt |
V |
12, 24, 42, 60, 96, 110,
180, 205, 220 |
42, 110, 120, 220,
50/60Hz |
| Allowed volt (allowance volt ) |
% |
±10 |
|
| Power requirement |
W |
35 |
- |
| Power keep |
VA |
- |
90 |
| Power impetus |
VA |
- |
550 |
| Work repeating |
|
Continuous |
Continuous |
| Time repeating press on |
ms |
40 to 60 |
15 to 25 |
| ISO 6403
off |
ms |
20 to 30 |
20 to 30 |
| Switching frequency |
time/h |
15000 |
7200 |
|
Insulation degree according to DIN40050 |
IP65 |
IP65 |
| Coil temperatare |
℃ |
To +150 |
To+180 |
| It is correlative stipulated electric wire must be grounded |
|
|
|
|
Characteristic curve (be measured when ν=41mm2 /s t=50℃)
|
|
|
|
|
|
Function limit (be measured when ν=41mm2 /s
t=50℃)
|
|
|
Function limit for giving is useful for valve bearing two directions flow at the same time (such as from P to A, B to T at the same time)
Because of producing flow strenth in the va;ve allowance function limit may be reduced more for single direction flow (such as from P to A, B port is
plugged)
This working limit is measured when solenoid is on working temperature owing volt 10% and no return pressure
|
|
|
Valve with DC solenoid
|
|
|
|
|
|
Valve with AC solenoid
|
|
|
|
|
External dimensions: valve with DC solenoid cooperated with surface fine machining requirement
|
|
|
|
|
|
1.three –way valve 1)
2. two- way valve with one solenoid (A,C,D,EA…)1)
3. two- way valve with one solenoid(B,Y,EB…)1)
4.plug of valve with one soleniol
5.1 solenoid “a”(grey plug-in connector)
5.2 solenoid “b”(black plug-in connector)
6.take off solenoid for space request
7.plug-in connector according to DIN43650 (rotatable 90 degrees)
8.take off plug-in connector for space request
9.take of manual urgent operation
10.name plate
11.o-ring 12X2
12.it can mount adding-connector (TB) on oil block if necessary
13.mounting surface according to DIN24340, A type
ISO 4401 and CFTOP-RP 121H
bed plate
G66/01(G3/8”)
G67/01(G1/2”)
G534/01(G3/4”)
fixed screw of the valve M6X50 GB70-85-10.9
tighten torque MA=15.5Nm
1)size without manual urgent operation
|
|
External dimensions: valve with AC solenoid cooperated with surface fine machining requirement
|
|
|
|
|
|
1.three –way valve 1)
2. two- way valve with one solenoid (A,C,D,EA…)1)
3. two- way valve with one solenoid(B,Y,EB…)1)
4.plug of valve with one soleniol
5.1 solenoid “a”(grey plug-in connector)
5.2 solenoid “b”(black plug-in connector)
6.take off solenoid for space request
7.plug-in connector according to DIN43650 (rotatable 90 degrees)
8.take off plug-in connector for space request
9.take of manual urgent operation
10.name plate
11.o-ring 12X2
12.it can mount adding-connector (TB) on oil block if necessary
13.mounting surface according to DIN24340, A type
ISO 4401和CFTOP-RP 121H
bed plate
G66/01(G3/8”)
G67/01(G1/2”)
G534/01(G3/4”)
fixed screw of the valve M6X50 GB70-85-10.9
tighten torque MA=15.5Nm
1)size without manual urgent operation
|
|
Connection bed plate
|
|
|
|
|
|
|